iSixSigma

Attribute U -Chart Appropriate?

Six Sigma – iSixSigma Forums Old Forums General Attribute U -Chart Appropriate?

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #48402

    sirrios
    Member

    We have an assembly and final test station were we are experiencing a high failure rate. The process consist of assembling together various subassemblies to create a complete system which is then tested (various different test). I want to use a U -Chart to monitor this process as I get different type of failures (failure mode) per system tool. We build between 1- 4 different types of systems per day and record the mfg. date, sales order#, type of failure, and # of occurrences. Is the U – Chart the appropriate attribute chart to use? I am confused because one data point could be made up 3 minor failures and the other (next build) 3 major failures. Instead, should I then use an SPC chart were the failures are weighed on the the type of defect?  

    0
    #163005

    annon
    Participant

    S,
    If you go to the blue bar to your left under Statistics and Analysis you will find a great deal of helpful information on SPC.  Good luck.

    0
    #163457

    fake accrington alert
    Participant

    U-Chart  is  used  for  defects at  various sample  size,for  attribute  data (fail/pass).

    0
    #163461

    DoNotKnowSixSigma
    Participant

    You can use u-chart because this focuses on defects BUT try to partner this with a pareto chart so that you can dissect the different defects that have occurred.

    0