  • #48157

    A.S.
    Participant

    Why Cpk should be grater than 1.33 or 1.67.How this number 1.33 and 1.67 arrived what is the basis.

    0
    #161311

    fake accrington alert
    Participant

    Cp 1.33 is  equal to  Sigma  4
    Cp 1.67 is  equal  to Sigma  5

    0
    #161317

    Kanwal Pradeep Kapur
    Participant

    When we are able to fit 6S.D between Mean & Nearest Specification to mean, we claim that we are operating at Six Sigma. Similarly if there is 5 S.D between nearest specification and the mean we say that process is operating at 5 sigma. The Cpk for 5 Sigma Operation is 5*S.D/3*S.D= 1.67 and similarly for a 4 sigma operation it is 4*S.D/3*S.D= 1.33. If we are not operating in a monopolistic market it is essential to have our process having sigma level >3.Hope this will give reasonable clarity.

    0
    #161328

    Mikel
    Member

    I prefer to be in a monopolistic market – to heck with the stat
    nonsense.

    0
    #161404

    A.S.
    Participant

    thanks a lot kanwal .
    anbu
     

    0
    #161412

    Kanwal Pradeep Kapur
    Participant

    Dear Stan,
                It is merely a wishful thinking. Reality is different. Be realistic you will feel at home.