iSixSigma

True Position

Six Sigma – iSixSigma Forums Forum Basics Welcome True Position

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #54410

    Sergio
    Guest

    When you have two holes that should be within true position with each other, and the Print shows “E” true position, diameter.010 MM, ABDMM. “D” true position, diameter .010 MM. Can you add the MM bonuses for each hole to increase the tolerance for the true position?

    Sergio

    0
    #195359

    Mike Carnell
    Participant

    @sergaguilar In my entire life I have only ever met one person who understood how to apply GDT with statistical analysis and that person is NOT me. If you are still struggling with this and want to contact me (mike.carnell@csintlinc.com) it will provide you with their email address. (I do not know if they want it published on the DF so this is meant to be a courtesy to them).

    0
    #195363

    MBBinWI
    Participant

    @sergaguilar – so long as the hole diameters have been properly sized so that at MM condition you still have sufficient material for the application, then yes, you can.

    0
    #195369

    Mike Carnell
    Participant

    @sergaguilar That would be two people now. If @MBBinWI is willing to answer, I have enough history with him to know he knows what he is talking about particularly when it comes to Mechanical Engineering stuff.

    0
Viewing 4 posts - 1 through 4 (of 4 total)

You must be logged in to reply to this topic.